A2 & B Series Air to Water Heat Pump

A2 & B Series Air to Water Heat Pump
A2 & B Series Air to Water Heat Pump
prev
  • A2 & B Series Air to Water Heat Pump
  • 1
  • 3
  • 4
next
  • A2 & B Series Air to Water Heat Pump
  • Applicable Place: Home,Villa, Etc.
  • Running Mode: DHW, Heating, or Cooling
  • Heating Output(KW): 5~28
  • COP: 4~5
  • Power Supply: 220V/50HZ or 380V/50HZ
  • Running Temperature range(ºC): -15~43
  • Max. Water Temperature(ºC): 60
  • Refrigerant Type : R410A
  • Delivery Time: 25~35 days
  • Inquire Online

Product Information

Air to Water Heat Pump – A2 & B Series

Products features and advantages:

1. DHW and house heating function, cooling is optional in B series
        

2. Use eco-friendly refrigerant R410A;



3. Use bigger heat exchanger with higher efficiency – COP exceeds 4.0 at Air 7℃ /Water35℃;

* Use famous components, like Japanese brand compressor, Emerson ALCO expansion valve, Siemens electric, etc., high quality and reliability
* Emerson expansion valve keeps the most suitable refrigerant flow in any case.
* SWEP stainless steel plate heat exchanger, 100% stainless water circuit


4.  Intelligent microprocessor control with heating curve, which is especially good for house heating and can reduce electricity consumption furthermore. 


5. Perfect protection design such as anti-frost protection, high/ low pressure protection, water flow protection, high-temp protection, etc., and automatic defrost function, assuring the system to run safely and efficiently even in hard conditions

6. Electric protection class IPX4

7. CE-RoHS certification by TUV
     

Products Specifications:
Models  No RJ(P)-80H/N2
RJ(P)-110H/SN2 RJ(P)-140H/SN2 RJ(P)-160H/SN2 RJ-220H/SN2 RJ-280H/SN2
Heating Capacity/Power Input (KW) [1] at A7/W35ºC [2] 8.4/1.9 11.5/2.8 14.3/3.4 16.8/3.8 21.8/5.1 27.8/7.1
at A2/W35ºC [2] 7.4/1.9 10.0/2.8 12.4/3.4 14.5/3.7 18.6/5.1 24.0/7.0
at A7/W45ºC [2] 8.2/2.2 11.0/3.4 13.6/4.2 16.0/4.5 20.9/6.0 26.9/8.0
at A15/W50ºC [2] 9.8/2.5 12.9/3.8 15.9/4.6 18.8/5.1 25.0/6.6 31.9/8.5
at A7/W50ºC [2] 8.1/2.4 10.7/3.7 13.2/4.5 15.7/4.9 20.3/6.5 26.8/8.5
at A2/W50ºC [2] 7.1/2.4 9.5/3.7 11.7/4.5 13.7/4.7 18.0/6.6 23.7/8.4
at A-7/W50ºC [2] 5.3/2.2 7.0/3.7 8.6/4.5 9.8/4.5 13.5/6.4 17.7/8.4
Cooling Capacity/Power Input(KW) at A35/W18ºC [2] 9.2/2.6 12.3/3.5 15.1/4.3 15.9/5.3 22.7/7.0 31.8/9.6
at A35/W7ºC [2] 7.0/2.3 9.5/3.1 11.6/3.8 14.0/4.7 18.0/6.2 24.6/8.7
Max.Power Input (KW) 3.1 4.7 5.7 6.4 8.4 10.7
Max.Current (A) 14.2 6.8 8.2 9.8 12.8 16.3
Electric Supply 220V/50HZ 220V/50HZ or 380V/50HZ 380V/50Hz
Max.water Temperature (ºC) 60
Running Temperature range (ºC) -18~43
Refrigerant Circuit Refrigerant R410A(Kg) 3.35 3.8 5.3 5.3 5.6 6.5
Compressor Type Rotary Scroll Scroll Scroll Scroll Scroll
Heat Exchanger High Efficiency fin-tube heat exchanger
Fan Motor  (W) 150 250 150x2 150x2 250x2 250x2
Air Flow (M3/H) 3000 4000 5500 5500 7500 7500
Water Circuit Heat Exchanger SWEP brand plate heat exchanger
In/Out Pipe DN25(1'') DN25(1'') DN25(1'') DN32(1-1/4") DN32(1-1/4") DN32(1-1/4")
Water Flow (M3/H) ≥1.1 ≥1.5 ≥1.9 ≥2.2 ≥3.0 ≥3.8
Pressure Loss (Kpa) 13 14 15 15 18 22
Permitted Pressure 0.8MPa
Unit Dimensions   WxHxD (MM) 1090*875*400 1090*960*400 1090*1260*400 1090*1260*400 1090*1430*400 1090*1430*400
Net Weight (Kg) 95 128 133 135 155 190
Noise Level at 1m/4m/10m (dB(A) 54/42/34 56/44/36 58/46/38 58/46/38 60/48/40 60/48/41
Note:
[1]The data of stable running condition (when defrosting,the average heating capacity reduces about 10% compare to corresponding data)
[2]Surrounding air temperature/ outlet water temperature 

Messages